SRL16_1

16-Bit Shift Register Look-Up-Table (LUT) with Negative-Clock Edge

XC3000
XC4000E
XC4000X
XC5200
XC9000
Spartan
SpartanXL
Spartan2
Virtex
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Primitive
Primitive

SRL16_1 is a shift register look up table (LUT). The inputs A3, A2, A1, and A0 select the output length of the shift register. The shift register may be of a fixed, static length or it may be dynamically adjusted. Refer to “Static Length Mode” and “Dynamic Length Mode” in the "SRL16" section.

The shift register LUT contents are initialized by assigning a four-digit hexadecimal number to an INIT attribute. The first, or the left-most, hexadecimal digit is the most significant bit. If an INIT value is not specified, it defaults to a value of four zeros (0000) so that the shift register LUT is cleared during configuration.

The data (D) is loaded into the first bit of the shift register during the High-to-Low clock (CLK) transition. During subsequent Low-to-High clock transitions data is shifted to the next highest bit position as new data is loaded. The data appears on the Q output when the shift register length determined by the address inputs is reached.

Inputs
Output
CLK
D
<SR(1)>
<SR(i)>
Q
1
X
No Chg
No Chg
No Chg
0
X
No Chg
No Chg
No Chg

D
D
SR(i-1)
SR(L)
SR(1) = contents of first shift register
SR(i) = contents of the i'th shift register stage (2<= n <= L)
L = shift register length (1 through 16 determined by (8*A3) +(4*A2) + (2*A1) + A0 +1)